Commercial Building Telecommunications Cabling Standard
The latest standard published by TIA is the ANSI/TIA/EIA 568-B standard. It is a revision of the ANSI/TIA/EIA-568-A that was published in 1995. It includes the core document, all five existing addenda and TSB-67, TSB-72, TSB-75 and TSB-95. This standard is published as a 3-part document:
The TIA/EIA-568-B.1 discusses general requirements. It provides information in regards to planning, installing and verifying structured cabling systems in commercial buildings. It also establishes performance parameters for cabling systems such as channels and permanent links. One of the major changes in this document is that it only recognizes Category 5e (or higher category) cabling for the second data outlet.
The TIA/EIA-568-B.2 discusses balanced twisted-pair cabling components. This standard specifies cabling components and transmission requirements for a cabling system.
The TIA/EIA-568-B.3 discusses optical fiber cabling components. This standard specifies components and transmission requirements for optical fiber cabling systems.
The purpose of this standard is to provide the minimum requirements for telecommunications cabling within a commercial building or campus environment.
The standard addresses the six major components of a structured cabling system:

Scope of ANSI/TIA/EIA-568-B

BACKBONE DISTRIBUTION
The function of the backbone distribution is to provide interconnection between telecommunications rooms, equipment rooms and entrance facilities to serve the needs of tenants in one or multiple buildings.
The components involved in backbone distribution include:
General Design Guidelines
Planning should consider the maximum amount of backbone cable, media additions (optical fiber) and number of connections required during a period spanning from three to ten years.
Consider the proximity of metallic cables to possible sources of electromagnetic interference.
Topology
The backbone distribution system is to follow a hierarchical star topology.
There cannot be more than two hierarchical levels of cross-connect.
Systems designed for non-star configurations (ring, bus or tree) can usually be accommodated by the hierarchical star topology.
Recognized Backbone Distribution Media
Recognized media may be used individually or in combination.
These media are:
Media Selection Criteria
The choice of backbone distribution media will depend on the characteristics of specific applications. Factors to consider in making a selection include:
In-Building and Inter-Building Backbone Cabling Distances
Recommended maximum distances are application and media dependent. It is not assured that all applications will function properly over the specified distances.
| Media Type | Horizontal Cross-Connect to Main Cross-Connect | Horizontal Cross-Connect to Intermediate Cross-Connect | Main Cross-Connect to Intermediate Cross-Connect |
| UTP | 800 m (2,624 ft) | 300 m (984 ft) | 500 m (1,640 ft) |
| 62.5/125 µm or 50/125 µm optical fiber | 2,000 m (6,560 ft) | 300 m (984 ft) | 1,700 m (5,575 ft) |
| Single-mode optical fiber | 3,000 m (9,840 ft) | 300 m (984 ft) | 2,700 m (8,855 ft) |
Note: These maximum backbone distribution distances are the values found in the ANSI/TIA/EIA-568-B.1 Standard.
HORIZONTAL CROSS-CONNECT
The termination of horizontal cable is the primary function of the horizontal cross-connect that is housed in a telecommunications room. Cable of all media types are terminated on compatible connecting hardware. Backbone cable is also terminated on compatible hardware. Connecting hardware, jumper wire and patch cords are collectively referred to as the horizontal cross-connect.
Telecommunications Room Functions
The primary function is to contain horizontal cable terminations of all recognized types.
Recognized types of backbone cable are also terminated here. Cross-connections of horizontal and backbone terminations using jumper wire or patch cords allow for flexibility to extend services to telecommunications outlet/connectors. The intermediate or main cross-connect for portions of the backbone cabling system may also be found in the telecommunications room separate from the horizontal cross-connect.
Cross-Connections and Interconnections
Moves, add-ons or changes are to be completed by performing cross-connects or interconnects. Cross-connects are connections between horizontal cabling and backbone or equipment connecting hardware. Connections made directly between equipment and horizontal cabling are called interconnects.
HORIZONTAL DISTRIBUTION
Horizontal distribution is the part of the telecommunications cabling system running from the work area to the horizontal cross-connect in the TR.
Horizontal cabling includes:
Note: May also include a multi-user telecommunications outlet assembly (MUTOA) or a consolidation point (CP).
General Design Guidelines
The horizontal distribution system must satisfy current requirements and should facilitate ongoing maintenance and relocation. Also consider future equipment and service changes.
Topology
The horizontal distribution system must follow a star topology.
Distances
Regardless of the media type used for horizontal distribution, the maximum distance is 90 m (295 ft).
Recognized Horizontal Distribution Media
Recognized media may be used individually or in combination.
These media are:
Hybrid cables (multiple types of media under a single sheath) may be used in the horizontal distribution system if each recognized cable type meets the transmission requirements and color-code specifications for that cable type.
Media Selection Criteria
Each work area must be equipped with at least two telecommunications outlets/connectors.
One outlet may be associated with voice and the other with data.
The second outlet shall be one of the following media:
WORK AREA
Work area components are from the outlet to the work area equipment. It is assumed a maximum of 5 m (16 ft.) is used for the modular cord at the work area. Four-pair UTP cables are terminated in 8-position modular jacks at the work area. The pin/pair assignments are referred to as T568A and T568B.
Work Area Components
Copper telecommunications outlet/connector
Work area components fall outside the scope of the standard. Work area equipment includes a large variety of equipment. Included are telephones, fax machines, data terminals and computers. Work areas are generally considered to be non-permanent, and are expected to change. Therefore, work areas should be designed to be relatively easy to change.
Telecommunications Outlet/Connector
Pin/pair assignment for 100 ohm UTP cable is recommended to follow the T568A or the T568B configuration. These configurations, shown in the illustration below, depict the front view of the telecommunications outlet/connector.
It is important to use only one pin/pair configuration (either T568A or T568B) for any given link or channel, and preferably for the entire building.
Eight-position jack pin/pair assignments
Optical fiber telecommunications outlet/connector
The optical fiber cable used in horizontal cabling shall be terminated at the work area with a duplex optical fiber outlet/connector.
Work Area Cords
The horizontal distribution system assumes a maximum cord length of 5 m (16 ft).
Cables and connectors should meet or exceed patch cord recommended requirements.
Special Adaptations
If application specific adaptations such as impedance matching devices are required, they must be external to the telecommunications outlet/connector.
Some commonly used adapters include the following:
Consider adapter compatibility with premises cabling and equipment. Adapters may have detrimental effects on the transmission performance of the telecommunications cabling system.
HORIZONTAL CABLING FOR OPEN OFFICES
A horizontal cabling termination point (multi-user telecommunications outlet assembly) and/or intermediate horizontal cabling interconnection point (consolidation point) provide more flexibility in open office layouts with modular furniture, where frequent office rearrangements are performed. Both the multi-user telecommunications outlet assembly and the consolidation point shall be located in a fully accessible, permanent location.
Multi-User Telecommunications Outlet Assembly
The multi-user telecommunications outlet assembly (MUTOA) is a termination point for the horizontal cabling, consisting of several telecommunications outlets in a common location. The modular line cord extends from the MUTOA to the terminal equipment without any additional intermediate connections. This configuration allows the open office plan to change without affecting the horizontal cabling. 
Multi-User Telecommunications Outlet Assembly
The following guidelines shall be followed when installing a MUTOA;
| A m (ft.) | B m (ft.) | C m (ft.) | Total Channel m (ft.) |
| 5 (16) | 90 (295) | 5 (16) | 100 (328) |
| 5 (16) | 85 (279) | 9 (30) | 99 (325) |
| 5 (16) | 80 (262) | 13 (44) | 98 (322) |
| 5 (16) | 75 (246) | 17 (57) | 97 (319) |
| 5 (16) | 70 (230) | 22 (72) | 97 (319) |
| Horizontal and Work Area 24 AWG UTP Cabling Lengths | |||
Consolidation Point
The consolidation point (CP) is an interconnection point within the horizontal cabling. The consolidation point performs a "straight-through" intermediate interconnection between the horizontal cabling coming from the horizontal cross-connect and the horizontal cabling going to a MUTOA or the telecommunications outlet in the work area. Cross-connection between these cables is not allowed. A consolidation point may be useful when reconfiguration is frequent. but not so frequent as to require the flexibility of MUTOA.
Consolidation Point
The following guidelines shall be followed when installing a consolidation point;
Channel Test Configuration
Channel testing is used to verify the performance of the overall channel.
The channel includes the following components:
The total length of equipment cords, patch cords and jumper wires and work area cords is not to exceed 10m (33 ft.)
Channel Test Configuration
Permanent Link
The permanent Link test configuration represents the permanently installed cabling. It includes:
The permanent link excludes both the cable portion of the field test instruments cord.
Permanent Link Test Configuration
Parameters discussed in the document for channel and permanent links are:
Category 5 Cabling Transmission
Since the minimum requirement for copper cabling systems is now Category 5e cabling systems; in the ANSI/TIA/EIA-568-B.1, there is an informative annex that provides cabling transmission performance for Category 5 legacy systems.
The important parameters to meet are the Return Loss and the EXFEXT. If an existing Category 5 installation fails either Return Loss or the ELFEXT parameters given in the ANSI/TIA/EIA-568-B.1, annex D, corrective actions should be taken. The document specifies different options to correct the failure. Select the options(s) which is the most appropriate to your solution.
Testing should be performed with an enhanced level II (level II-E) field tester or better.
Optical Fiber Cabling Transmission Performance
Minimum recommended performance for a multimode or single-mode optical fiber cabling system are described in this standard.
A typical Link segment is found between the telecommunications outlet/connector and the horizontal cross-connect. The link segment includes.

Link Configuration
The single performance parameter for optical fiber cabling system is the link attenuation. It is the only parameter that can be affected by the installation and can be tested in the field. Depending on the application, a budget loss is allocated for the link segment.
Centralized Optical Fiber Cabling
The purpose of the centralized optical fiber cabling system is to provide a fiber-to-the-desk cabling system utilizing centralized electrons versus the traditional method of distributing the electronics to the individual floors.
Work area connections are extended to the main cross-connect by utilizing either pull-through cables, an interconnect or a splice in the telecommunications room. Use of an interconnection between the horizontal and backbone cabling provides the greatest flexibility, ease of manageability and can easily be migrated to a cross-connect.
The maximum horizontal cabling length is specified at 90m (295 ft.). The distance of horizontal and backbone cabling combined with work area cords, patch cords and equipment cords is not to exceed 300m (984 ft.).
Centralized cabling systems shall be located within the same building of the work areas being served. All move and change activity shall be performed at the main cross-connect. Horizontal links may be added and removed in the telecommunications room.
When using the pull-through method, the cable is to have a continuous sheath from the work area through the telecommunications room to the centralized cross-connect. The pull-through cable length shall be limited to 300m (984 ft.).
When designing a centralized cabling system, provisions shall be made to allow for the migration from pull-through, interconnect or splice to a cross-connect implementation. To facilitate this migration, sufficient space shall be left in the telecommunication room for additional patch panels. In addition, adequate cable slack shall be left in the telecommunications room to allow for the cables to be moved to the cross-connect location.
Slack can be stored as either cable or unjacketed fibers. When storing slack, provisions shall be made to ensure bend radius limitations are not violated. Cable slack can be stored within an enclosure or on the wall of the telecommunications room. Protective enclosures shall be used when storing slack fibers.
When planning the wall-mount or rack-mount layout, provisions should be made to allow future growth.
When sizing backbone cabling, provisions should be made for future horizontal links thereby minimizing the need for additional backbone cables. The backbone fiber count should be capable of supporting present and future networking technologies. Typically two fibers are required for each application connection required at the work area.
New Published Addenda:
ANSI/TIA/EIA-568-B.2 addendum 1
This addendum provides the Category 6 requirements for channel and permanent links. The Category 6 cabling systems are part of the ANSI/TIA/EIA-568-B core document and follow all the structured cabling requirements, for example, topology, recognized media type, horizontal and backbone design requirements including the work area.
ANSI/TIA/EIA-568-B.2 addendum 2
This addendum is a revision of sub-clause 4.3.4.8, 4.4, 4.4.1, 4.4.4.9 and 5.4.3 of the ANSI/TIA/EIA-568-B.2 document regarding the NEXT parameter equation for Category 3 cables.
ANSI/TIA/EIA-568-B.2 addendum 3
This addendum is a revision of clause 1.2.5 regarding additional considerations for insertion loss and return loss pass/fail determination.
ANSI/TIA/EIA-568-B.3 addendum 1
The purpose of this addendum is to provide additional transmission performance specifications for 50/125 µm optical fiber cable capable of supporting 10 Gb/s serial transmission up to 300m (984 ft.) using 850 nm nominal wavelength lasers. The fiber is called 850 nm Laser-Optimized 50/125 µm multimode optical fiber cable.